Not known Facts About Dp50rb login
Not known Facts About Dp50rb login
Blog Article
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
1.2.2 Warning Labels Warning Labels That means You should carefully read this manual in advance of use gadget. The next labels are a. Never location the machine over a sloped surface area. Or else the obtainable once the program system could slide, leading to individual damage or even the gadget is effective Using the cell malfunction.
A smart new shape, Increased mobility and handy operation make DP-fifty compatible for all scientific options.
.. Page 161 The indicator over the printer Glitches manifest when the adapter turns orange, and the printing printer adapter operates. Disconnect and link the fails. electrical power adapter, electrical power over the printer adapter yet again, and validate whether or not the printing is normal immediately after one minute. Web site 163: Electrical Security Inspection
Mindray respects your privateness. We use cookies for a number of needs, for example Web page functionality, improving your knowledge of our Web-site, making integration with social networking and supporting target our promoting.
five.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy Test Action: Do adjustments as the way in which in testing the utmost depth. Document the space by 20mm each phase about the longitudinal targets line utilizing the measurement caliper; Pick out the worth with the greatest error (to 20mm), determine the precision using the formula underneath The measurement caliper ought to be positioned for the upper fringe of the target, Be aware:... Webpage 79 Transverse geometric positioning accuracy Exam Step: Deal with the scan floor from the phantom with h2o or couple gel, Carefully contact the probe Using the scan area Modify the depth, earning the transverse targets being shown inside the image. Change the main target level being posited beside the transverse targets (the normal isn't clear) Change parameters like acquire, TGC, building Each individual transverse targets to be Obviously exhibited. Webpage eighty 5.5.two.4 Blackout Place Test Stage: Deal with the scan floor with the phantom with h2o or couple gel, gently contact the probe with the scan surface Change the depth at a reduce value, and established the main target at the nearest place to the scan surface area. Minimize the value of parameters like AP, Achieve till the history sounds just could be witnessed. Webpage eighty one: Program Update And Upkeep
Notice: Prior to inserting the connector to the probe port, inspect the connector pin. If your pin is bent, don't make use of the probe right up until it has been inspected / fixed / replaced. Installing Peripherals For the styles of your supported peripherals, make sure you seek advice from “two.
Simply click Agree and Commence to simply accept cookies and go Dp50rb login directly to the site or click on More details to view comprehensive descriptions of the categories of cookies and select no matter if to just accept particular cookies whilst on the location.
The chapter materials the method to validate major function and general performance of merchandise. This is often only useful for reference, not preventive execution. Operate examining and tests of this portion shall be performed by Mindray services engineers plus the person with each other. Website page sixty six: General Exam
Skip to material Make sure you Be aware this Web-site is not really optimized for your browser you're presently utilizing, Internet Explorer eleven, and Therefore some factors my not seem as designed.
This manual might referring to details guarded by copyright or patents and will not convey any license underneath the patent legal rights or copyright of Mindray, or of Some others. Site nine: Statement
NOTE: Be sure that you could pull out and push in the IO board sockets vertically when pulling out and assembling the IO board assembly within the position with the take care of. Clear away panhead screws with washers M3X6 (4) accustomed to safe the IO board, then you could potentially just take out the IO board. Web site 116 Take away panhead screws with washers (two M3X6) that are mounted on the primary unit, acquire out the higher baffle and then pull out two cables connecting the main board to the ability module assembly.
We’re below to advocate for adjust that removes roadblocks and inspires a better Health care program.
Written content Approach Check out the battery periodically : a) Check if battery could be billed Commonly when energy-on: That The present ability is one hundred% or ability raises after a brief time indicates that the battery might be charged Generally.
Effectiveness Exam five.five.one Check Process Resolution Detection depth Geometric Situation Accuracy Blackout spot check Report the exam illustrations or photos 5.5.two Examination Articles The graphic utilised here is only for reference, persist with the image result in the true Take note: scenario. Necessities: Display screen: established the distinction and brightness in the medical application worth (or perhaps the default status) Procedure environment: dark space, simulating the medical software setting. Site 76 In situation the transverse resolution screening targets are horizontally exhibited, history the small length of two targets which can be Plainly recognized. Repeat the operation previously mentioned with the transverse resolution testing targets at other depths. As proven in figure below. Axial resolution ... Page seventy seven When using the convex probe, hold the transverse resolution testing targets to notice: be displayed close to the midline. When utilizing a linear probe with steer function, never turn on the steer operate when accomplish the transverse resolution test. Zoom within the region where by the targets Situated if needed. The diameter on the goal position at a particular depth is equal to the transverse resolution at the depth. Site 78 five.